GE IS200ESYSH3A I/O Terminal Board
plcru@foxmail.com
+86 18185397189
GE IS200ESYSH3A I/O Terminal BoardFunctional designation: ESYSProduct family: EX
GE IS200ESYSH3A I/O Terminal Board
Functional designation: ESYS Product family: EX2100e Excitation Control System Manufacturer: GE Industrial Systems, USA Control architecture: Simplex control, Group H3, M1 control section Reference documentation: GEI-100772, GEH-6784D, GEH-6781L
General Description
IS200ESYSH3A is the main field I/O interface board for the GE EX2100e generator excitation regulator system. It collects generator current transformer and potential transformer feedback signals, auxiliary contact status signals, and provides trip relay output drives. All I/O signals are transmitted to the main regulator controller via the HSLA high-speed serial link daughterboard mounted on this board. This board covers most of the field wiring termination requirements for the simplex EX2100e excitation cabinet, applicable to both regulator and static excitation configurations.
I/O Allocation
Generator CT inputs: 2 channels, configurable for 1A or 5A secondary current Generator PT inputs: 2 sets three-phase voltage inputs Auxiliary contact inputs: 7 channels, wetting voltage 24/48/125V DC, powered from board 55V DC supply Trip relay outputs: 2 Form-C relay contacts, designed for lockout and trip functions, rated for 125V DC coil driving Signal conditioning: Integrated isolation transformers for CT and PT galvanic isolation
Electrical Interface
Main power supply: 55V DC, supplied by the EPDM power module of the M1 control rack Communication connectors: 6 off D-Sub connectors for HSLA high-speed serial link daughter board connection Termination type: Screw barrier terminal strips, wire range #12 AWG to #24 AWG Status indication: Onboard LED indicators for each contact input channel
Environmental and Mechanical
Mounting method: Chassis fixed installation inside the excitation control cabinet Operating temperature range: 0°C to +60°C Storage temperature range: -40°C to +85°C Coating: Conformal coating available on AAA revision variants for harsh plant environments Approximate net weight: 0.45 kg
Application Notes
This variant is simplex only and cannot be used in redundant dual-channel EX2100e configurations. CT and PT wiring must follow generator protection and excitation earthing rules to avoid common mode interference. All relay output circuits require external fusing matching the load rating. HSLA daughterboard must be properly seated to establish serial communication with the main control card.