• WOODWARD 8237-2597 PROTECH-GII Overspeed Protection Device
  • WOODWARD 8237-2597 PROTECH-GII Overspeed Protection Device

WOODWARD 8237-2597 PROTECH-GII Overspeed Protection Device

Delivery time 3 days

Product origin New/used

Email plcru@foxmail.com

Mobile/wechat /WhatsApp +86 18185397189

I. Basic Product InformationModel: 8237-2597 (ProTech-GII with Math Enhancement

WOODWARD 8237-2597 PROTECH-GII Overspeed Protection Device

I. Basic Product Information


Model: 8237-2597 (ProTech-GII with Math Enhancement Function), original Woodward TMR tri-mode redundant overspeed protection device, SIL3 safety rating, compliant with API670/API612 and IEC61508 standards, specifically designed for overspeed protection tripping of steam turbines/gas turbines, water turbines, reciprocating machines, and compressors.


Power Supply: Single module compatible with 90~240VAC wide voltage range; 24VDC auxiliary power supply optional for the whole unit.


Structure: Three completely independent measurement modules (A/B/C), panel-mounted (rack mounting only).


Speed Range: 0.5~32000RPM, speed measurement accuracy ±0.25%, trip response **≤12ms**


II. Core Hardware Architecture (Standard configuration for 8237-2597)


Speed Input: 2 MPU magnetoelectric speed probes per module (compatible with active/passive magnetic pickups), up to 6 speed signal acquisitions for the whole unit.


Trip Output: Two configurations (optional upon ordering).


2003-out-of-3 voting type (mainstream, standard configuration for 8237-2597): 2 sets of redundant trip relays, tripping triggered after logic voting by the three modules, no false tripping in case of single-point fault, meeting unit safety regulations.


Three-channel independent non-voting type: 1 each of A/B/C. Independent trip contacts for each of the three channels, ensuring no interference between them; ideal for redundant hydraulic trip circuits.


Auxiliary IO: Independent alarm relay, 4~20mA analog speed output, switch start/stop/reset input.


Communication: Standard Modbus-RTU, optional external gateway for Ethernet expansion; speed, alarm, and trip data upload to DCS/PLC.


III. Key Functions (8237-2597 Unique Math Enhancement Algorithm)


Overspeed + Over-acceleration Dual Protection: In addition to fixed speed tripping, configurable acceleration surge tripping can prevent rotor runaway faults; supports custom deceleration interlock protection.


Online Testing & Online Hot Maintenance: Single module faults can be hot-swapped for replacement; the remaining dual channels maintain unit safety without shutdown; panel buttons/Modbus. Remote simulation speed measurement to verify the integrity of the trip circuit.

Event storage: Timestamped trip logs and fault alarm records store overspeed trigger values, probe disconnection, power abnormalities, and module fault information for easy post-fault tracing.

Password hierarchical access control: Hierarchical encryption for parameter setting and trip setting modification to prevent accidental modification of protection settings.

Built-in simulation signal source: Built-in internal frequency generator allows for whole-machine calibration and verification without external probes.

IV. Typical application scenarios

Thermal power turbine generator sets, gas turbine combined cycle units

Hydropower turbine units, large reciprocating compressors in oil refining/chemical industries, drive turbines

Marine power turbines, industrial waste heat power generation turbine units

V. Differentiation within the same series

8237-2594: Basic version ProTech-GII (no Math mathematical operations)

8237-2597: Enhanced Math version, supports custom logic and multi-parameter linkage protection.

8237-2597.jpg

8237-2597..jpg


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy Agreement