Overview

Product model: VM600 CPUM, including specific models such as 200-595-100-014 and 200-595-072-122.

Functional positioning: It is the core control unit of the VM600 series vibration monitoring system, serving as a system controller and data communication gateway. It is used in the mechanical equipment protection system (MPS) and condition monitoring system (CMS), coordinating data from various sensors and modules to provide real-time vibration monitoring and protection, ensuring the reliable operation of critical mechanical equipment.

Vibro-meter 200-595-100-014 200-595-072-122 VM600 CPUM CPU Board VMF-CPUM.jpg

Electrical characteristics

Input voltage: There are multiple input voltage versions, including AC input (115/230VAC or 220VDC) and DC input (24VDC and 110VDC), etc. Some data also indicate that the input voltage range is 18-32VDC.

Power: Some data indicate that the power is 125W, while others mention that the power consumption is 10-15W.

Communication interface

Ethernet interface: A main Ethernet connector (8P8C (RJ45)) for communicating with the VM600 MPSX software and/or Modbus TCP and/or Profinet; An auxiliary Ethernet connector (8P8C (RJ45)) for redundant Modbus TCP communication.

Serial interface: A main serial connector (6P6C (RJ11/RJ25)), used for communicating with the VM600 MPSX software through direct connection; Two pairs of serial connectors (6P6C (RJ11/RJ25)) can be used to configure the VM600 rack as a multi-point RS-485 network.

Vibro-meter 200-595-100-014 200-595-072-122 VM600 CPUM CPU Board VMF-CPUM..jpg

Working environment

Operating temperature: Generally -20 °C to + 70°C, and some data also indicate -40 °C to + 85°C.

Storage temperature: -40°C to + 100°C.

Other features

Anti-interference performance: It has excellent anti-electromagnetic interference capability. Its housing design can resist external electromagnetic fields, ensuring that vibration measurements are not affected and guaranteeing the integrity of the data.

Durability: Designed to withstand harsh industrial environments, it can resist extreme temperatures, high humidity and mechanical shock, and can be installed in harsh conditions such as industrial sites, near heavy machinery or even outdoors.

Vibro-meter 200-595-100-014 200-595-072-122 VM600 CPUM CPU Board VMF-CPUM...jpg

Vibro-meter 200-595-100-014 200-595-072-122 VM600 CPUM CPU Board VMF-CPUM....jpg


Related products


Vibra-meter VM600/RPS6U/200-582-200-011 Vibration detection module

Vibro-meter VM600-IOC4T Input/output card

Vibra-meter VM600-RPS6U/200-582-500-013 Condition monitoring module

Vibro-meter 620-003-111-112 Detection module

Vibro-meter 620-002-000-113 Input/output card


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy Agreement