• Triconex 3626X 24VdcSupervised Digital Output
  • Triconex 3626X 24VdcSupervised Digital Output

Triconex 3626X 24VdcSupervised Digital Output

Delivery time 3 days

Product origin New/used

Email plcru@foxmail.com

Mobile/wechat /WhatsApp +86 18185397189

The Triconex 3626X (DO 3626X) is a 24V supervised digital output module in the T

Triconex 3626X 24VdcSupervised Digital Output

The Triconex 3626X (DO 3626X) is a 24V supervised digital output module in the Triconex TMR Safety Instrumented System (SIS), designed for Safety Intensive Lack of Technology (SIL 3) applications.


I. Core Specifications


Model: 3626X (DO 3626X)


Brand: Triconex (Schneider Electric)


Type: TMR Triple Modular Redundancy 24Vdc Supervisory Digital Output Module


Number of Channels: 16 independent outputs


Operating Voltage: 24 VDC (18-32 VDC)


Output Type: Solid State Relay / Dry Contact


Maximum Load: 0.5A / Channel @ 30V DC


Supervised Function: Supports line monitoring, detects open circuits, short circuits, and load faults


Isolation: Channel-to-channel / Field-to-System electrical isolation (1500 VAC)


Architecture: Triple Modular Redundancy (TMR), 2 out of 3 (2oo3) voting mechanism


Hot-Swapping: Supported, online maintenance without downtime


Safety Certification: IEC 61508 SIL 3


Operating Temperature: -40°C ~ +85°C


Installation: Tricon rack mount


II. Key Functional Features

TMR Triple Redundancy Architecture

Internal three independent circuits process in parallel, 2oo3 voting outputs, single-point failure does not affect the system

Automatic fault detection, isolation, and fault tolerance, system availability > 99.999%

Supervised Output

Real-time loop diagnosis: Continuously monitors output status and load loop integrity

Detectable: Line breakage, short circuit, load loss, external power failure

Triggers system alarms in case of fault, ensuring safe operation

Powerful Diagnostics

Each channel LED status indicator

Complete module health, channel, power supply, and field loop diagnosis

Safety Applications

Designed for Emergency Shutdown (ESD), Burner Management System (BMS), and Safety Interlocking System (SIS)

Directly drives solenoid valves, motors, indicator lights, and alarm loops

III. Typical Application Scenarios

Petrochemical: Safe shutdown and interlocking of reactors, compressors, and pumps

Power Plant: Boiler and turbine safety protection

Oil & Gas: Emergency shutdown of wellheads and pipelines

Metallurgy/Pharmaceutical: Safety control of high-risk processes

IV. Differences from Ordinary DO Modules

Supervised Monitoring: 3626X can actively detect line faults, which ordinary modules cannot.

TMR Redundancy: Triple circuitry + voting, SIL 3 safety level

High fault tolerance: Safe operation even in the event of a single/dual-channel failure

TRICONEX 组合.jpg

TRICONEX 8120X Main Chassis.jpg


Related products


TRICONEX 4210 DCS System Module

Triconex 9563-810 Safety System Card

TRICONEX 3000520-390C1R 9662-610 Interface Module

TRICONEX 3301 Input/Output Module

TRICONEX 3511 Communication Module


Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy Agreement