Emerson 1066-P-HT-60 | Rosemount Single Channel Transmitter
Delivery time 3 days
Product origin New/used
Email plcru@foxmail.com
Mobile/wechat /WhatsApp +86 18185397189
I. Basic InformationModel: 1066-P-HT-60Brand: Emerson (Rosemount)Type: Single-ch
I. Basic Information
Model: 1066-P-HT-60
Brand: Emerson (Rosemount)
Type: Single-channel analog transmitter (Supports measurement of parameters such as temperature, pressure, and liquid level, depending on sensor configuration)
Application scenarios: Signal conditioning and transmission in industrial process control, suitable for industries such as chemical engineering, oil and gas, power, and pharmaceuticals
Ii. Core Parameters
1. Input characteristics
Measurement type:
Supports input signals such as thermocouple (TC), thermal resistor (RTD), DC voltage (mV/V), and DC current (mA)
Typical configuration: If "P" in the model represents pressure/process parameters, it may be compatible with strain gauge pressure sensors
Input range:
Thermocouples: such as J, K, T, E, R, S, B types, etc. (Full range coverage)
Thermal resistors: PT100, PT1000, NI100, Cu50, etc. (Supporting 2/3/4 wire system)
Voltage: ±100 mV, 0-10 V, etc. (Depending on the model selection)
Current: 0-20 mA, 4-20 mA (Input impedance ≤250 Ω)
Accuracy:
Thermocouple: ±0.15% of reading (typical value)
Thermal resistance: ±0.05% of reading + 0.3°C (at 0°C)
Voltage/current: ±0.05% of full scale
2. Output characteristics
Standard output:
Analog signal: 4-20 mA DC (two-wire or three-wire system, load resistance ≤600 Ω@24 VDC)
Digital signal: Supports HART® 7 protocol (optional, for two-way communication and diagnosis)
Output resolution: 16 bits (corresponding to 0.015% of span)
3. Power Supply and Power Consumption
Power supply range:
Two-wire system: 10-30 VDC (typical operating voltage 24 VDC)
Three-wire system: 10-30 VDC (Independent power supply, output isolated from the power source)
Power consumption:
Typical value: ≤ 1.5W (without HART); ≤ 2.5W (with HART
4. Electrical characteristics
Isolation performance:
Three-terminal isolation of input/output/power supply (optional, to enhance anti-interference ability)
Noise suppression
Comply with the IEC 61000-4-2/3/4 standard and be resistant to radio frequency interference (RFI) and electromagnetic interference (EMI)
5. Machinery and Environment
Shell material:
Aluminum alloy (standard type) or 316 stainless steel (corrosion-resistant type, suitable for harsh environments)
Protection grade:
IP66/IP67 (NEMA 4X), supporting installation in outdoor or humid environments
Temperature range:
Operating temperature: -40°C to +85°C (wide-temperature type is optional)
Storage temperature: -40°C to +100°C
Vibration/Shock
Vibration: ≤5 g (10-150 Hz) Impact: ≤30 g (11 ms)
Iii. Functional Features
Flexible configuration
Parameter configuration (such as range, damping time, and unit switching) is carried out through the HART handheld controller or the Emerson AMS device manager.
Support linearization correction (such as nonlinear sensor compensation)
Diagnosis and Maintenance
It is equipped with an internal self-diagnostic function to monitor in real time the status of the sensor such as disconnection, over-range, and power failure
Support equipment health status monitoring (such as drift warning, component life prediction)
Industry compliance
Certifications: ATEX, IECEx (Explosion-proof), FM, CSA (Application in Hazardous Areas)
Comply with the ISO 9001 and ISO 14001 quality management systems
Iv. Key Points for Selection
Model Analysis:
1066: Product Series Number (Single-channel Transmitter)
P: Process parameter measurement (possibly corresponding to pressure/strain input)
HT: High-temperature version (The upper limit of the operating temperature has been raised to + 125° C. Confirmation required)
60: Output type (such as 4-20 mA+HART)
Key options:
Explosion-proof grade (such as Ex ia IIC T6 Ga)
Installation method (rail installation or on-site installation)
Communication protocol (HART and Foundation Fieldbus are optional)
Related products